Skip to content

01 · Your data

All your plant's history in one place, without a data project.

We connect read-only to what already collects your data and bring its history across, with names, units and limits.

  • Read-only connection

    Set up with your team. Nothing at the plant changes and no hardware is added.

  • Years of history

    Choose the readings and how far back. Big imports run in the background.

  • Picks up where it stopped

    If an import is interrupted it resumes on its own, and no reading is ever stored twice.

  • Stays up to date

    New data follows on its own, so checks and answers always use the latest readings.

  • Names, units and limits

    Each reading keeps its name, unit and normal range, so nothing has to be typed again.

Bringing in history · last 2 years

Example

71%

Resumes on its own if interrupted

  • Block A · 48 readingsDone
  • Block B · 52 readingsDone
  • Block C · 50 readings64%
  • Weather and meters · 14 readings22%
Units: kW, °C, W/m²Limits keptNo reading stored twice
How the connection works

02 · Checks

Problems found for you, with the reason attached.

Every reading is compared with its own normal behaviour, with similar days, with its neighbours and with its limits.

  • Seven checks on every reading

    From sudden drops to slow decline, run on the whole plant, not a sample.

  • Grouped by equipment

    Findings are grouped by inverter and block, so you see every problem area at once.

  • Each finding explains itself

    What it saw, since when, where, and the readings behind it.

  • Plain statistics

    Worked out with clear rules you can check, not guesses. The AI only explains them.

  • Check 1

    Sudden drops

    Output falls away from normal, then comes back.

  • Check 2

    Stuck sensor

    A value stops moving when it should change.

  • Check 3

    Out of range

    Beyond the limits set for the reading.

  • Check 4

    Missing data

    Readings stop arriving for a while.

  • Check 5

    Slow decline

    A little less every day, often dust.

  • Check 6

    Unsteady output

    Swings far more than it used to.

  • Check 7

    Repeated stops

    Equipment keeps tripping and restarting.

  • On/off equipment

    Gets only the checks that make sense for it, so a switch that rarely changes is never called stuck.

Needs a look

Example
What
String current on Inverter 7 fell to zero
Since when
Tuesday 11:20, still ongoing
Where
Block B · Inverter 7 · String 3
Evidence
The chart and the readings it used

03 · Charts

Any reading, any time range, in seconds.

One list of every inverter, string, meter and sensor, and charts that never mislead.

  • Readings list

    Status, trend, where the value sits in its range and when it last updated, for every reading.

  • Compare side by side

    Up to three readings in one view. Different units get their own panel, never a shared axis.

  • Gaps are gaps

    Missing data shows as a break, never as a line drawn across it.

  • Zoom, table and CSV

    Drag to zoom, step with the keyboard, switch to a table or download the data.

  • Quick search

    Jump to any reading, page or question from one search box.

Compare · Inverter 4

Example
Drag to zoomTable viewDownload CSV

AC power · kW

Heatsink · °C

The break in AC power is a real gap in the data, shown as a gap.

04 · Assistant

Answers in plain English that show their work.

Ask the way you would ask a colleague. The assistant reads the history, runs the checks and explains.

  • Grounded in your data

    Every answer comes from your plant's own readings, never from general knowledge alone.

  • Shows its evidence

    The readings and time window it used, listed with each answer.

  • Says how fresh the data is

    So an answer about this morning is never built on last week's data.

  • Your time zone

    Times are shown where you are, not where the server is.

  • Conversations are kept

    Come back to an earlier question and carry on.

Why did Block C make less yesterday?

Answer

Example

Inverter 4 stopped at 11:42 and restarted at 14:10, during the sunniest hours. The other inverters in Block C ran normally, so the loss is almost all from that one stop.

3 readings usedWindow 06:00 to 18:00Data up to 09:41 todayTimes in your time zone

05 · Approvals

You stay in charge of every change.

Read-only by default. If you allow it, the assistant can suggest a change, and only a person can approve it.

  • An allowed list with limits

    You choose which items may ever change, and the lowest and highest value for each.

  • A person approves

    Each suggestion waits for someone on your team. If nobody acts, it expires.

  • Checked twice

    Nexchain OS checks the limits, then your own plant system checks them again before applying.

  • A complete audit log

    Who suggested, who approved, what changed and when, day by day.

Who canAI assistantYour teamYour plant system
Read plant data
Suggest a change
Approve a change
Apply a change
Check limits again before applying
Show up in the audit log
Read the safety model

How it fits your day

One day with Nexchain OS

  1. 06:30

    Morning summary

    Before the sun is high, see yesterday's energy, which block fell behind and what needs a look today.

  2. 09:00

    Ask why

    Ask why Block C made less. Get the stop times of Inverter 4 and the readings behind the answer.

  3. 11:00

    Approve a change

    The assistant suggests limiting a hot inverter. A colleague reads the evidence and approves.

  4. 17:30

    Check the record

    The audit log shows what was suggested, who approved it and what the plant system did.

Every kind of plant

If its data is collected, we can read it.

The checks work on the readings, not on the shape of the plant. One rooftop or a portfolio of large sites, the features are the same.

  • A long row of ground-mounted solar panels in farmland

    Ground-mounted

    Large plants with many blocks and inverters.

  • Solar panels on the roof of an office building

    Rooftop

    Commercial and industrial roofs.

  • A solar carport shading parked cars

    Carports

    Parking shades that make power.

  • Sheep resting under raised solar panels

    Agrivoltaic

    Panels shared with farming and grazing.

What changes

The usual way, and with Nexchain OS

  • An inverter stops for a few hours

    Usually

    Noticed if someone sees a low daily total

    With Nexchain OS

    Listed next morning with the time it stopped and restarted

  • A sensor gets stuck

    Usually

    Found when a report looks wrong

    With Nexchain OS

    Flagged once it stops changing when it should

  • Dust builds up slowly

    Usually

    Rarely noticed until cleaning day

    With Nexchain OS

    Each block compared with its own earlier days

  • Someone asks why output fell

    Usually

    Export to a spreadsheet and scroll

    With Nexchain OS

    Ask, and get the readings and time window behind the answer

  • A setting needs to change

    Usually

    A phone call, and no record

    With Nexchain OS

    A suggestion, an approval and a full record

Good to know

What it does not do

  • Not an alarm system

    Findings come from stored history and update as data arrives. Keep your alarms and protection as they are.

  • Not a SCADA replacement

    Your control system stays in charge of the plant and keeps running exactly as before.

  • Never changes things on its own

    No change happens without a person's approval, and only for items you allow.

A technician on a lift working on a solar carport

See these features on your own plant.

Start now, or book a short demo and we will walk you through it.